Products Home Page
Search by
- Technical Data

- Code:

2004-2005 Catalogue (pdf)


FINDER S.p.A
Via Drubiaglio 14
10040 ALMESE (TO)
ITALY
Tel. +39 0119 346 211
Fax +39 0119 359 079
info@findernet.com 






   
On-line Technical Data: Timers and monitoring relays
 
For information and clarification regarding technical data on this page, please refer to the General Technical Information pages.
 
Serie87
 
1 delayed contact +1 instantaneous contact version available.
Dimensions (mm)78.8x22.5x96
Contact configuration1 CO 2 CO 2 pole
Rated current (A)5 8 5 8
Nominal voltage (V)250
Max voltage (V)400
Rated load AC1 (VA) 1250 2000 1250 2000
Standard contact materialAgCdO
Nominal voltage (VAC 50/60Hz)24÷240
Nominal voltage (VDC)24÷48
Rated power AC VA (50 Hz)1.5 5 1.5 5
Rated power DC W1.5 0.5 1.5 0.5
Functions BI AI, DI, GI, SW, BE, CE, DE, EE AI DI SW BE LI, PI, LE, PE BI AI, DI, GI, SW, BE, CE, DE, EE SD
Specified time range(0.15÷2.5)s, (0.5÷10)s, (0.07÷1.3)min, (0.5÷10)min (0.05÷1)s, (0.15÷3)s, (0.5÷10)s, (0.05÷1)min, (0.15..3)min, (0.5÷10)min, (0.05÷1)h, (0.15÷3)h, (0.5÷10)h, (3÷60)h (0.5÷10)s (0.05÷1)s, (0.15÷3)s, (0.5÷10)s, (0.05÷1)min, (0.15..3)min, (0.5÷10)min, (0.05÷1)h, (0.15÷3)h, (0.5÷10)h, (3÷60)h (0.15÷2.5)s, (0.5÷10)s, (0.07÷1.3)min, (0.5÷10)min (0.05÷1)s, (0.15÷3)s, (0.5÷10)s, (0.05÷1)min, (0.15..3)min, (0.5÷10)min, (0.05÷1)h, (0.15÷3)h, (0.5÷10)h, (3÷60)h (0.07÷1.3)min
Electrical life at rated load in AC1 (cycles)100·103
Protection categoryIP20
Ambient temperature range (°C)-20÷+60
Approvals: (according to type)CE GL GOST cULus
Unit weight (g)156
Boxed quantity (units)1

FUNCTIONS
U = Supply Voltage
S = Start
C = Relay contact (NO)
AE
ON delay: timing on START release (external start)
AI
ON delay
AIa
ON delay: (2 timed contacts)
AIb
ON delay: (1 timed contact + 1 instantaneous contact)

BE
OFF delay: timing on START release (external start)
BI
True OFF delay (power off)
CE
ON and OFF delay (external start)
DE
ONĘpulse: timing on START pulse
DI
ON pulse
DIa
ON pulse: (2 timed contacts)
DIb
ON pulse: (1 timed contact + 1 instantaneous contact)

for 86 Serie


for 87 Series

EE
OFF pulse: timing on START releasel
FE
ON pulse - OFF pulse: timing on Start pulse and on START release
GI
Fixed pulse (0.5 s) delayed
HI ON pulse
LE Asymmetrical recycler: pulse start (external start)
LI
Asymmetrical recycler: pulse start
PE
Asymmetrical recycler: pulse start (external start)
PI
Asymmetrical recycler: pause start
SD
Star - delta
SP
Symmetrical recycler: pause start
SW
Symmetrical recycler: pulse start


Finder SpA. - ITALY - Tel. +39 0119 346 211 - Fax +39 0119 359 079