Products Home Page
Search by
- Technical Data

- Code:

2004-2005 Catalogue (pdf)


FINDER S.p.A
Via Drubiaglio 14
10040 ALMESE (TO)
ITALY
Tel. +39 0119 346 211
Fax +39 0119 359 079
info@findernet.com 






   
On-line Technical Data: Timers and monitoring relays
 
For information and clarification regarding technical data on this page, please refer to the General Technical Information pages.
 
Serie85 86
 

Miniature Plug-in Timers Modules.
Dimensions (mm)20.6X27.7x62.6 10.5x15.8x34 38x10.5x54
Contact configuration2 CO 3 CO 4 CO see 40/44/55/60/62 series relay see 60/62 series relay
Rated current (A)10 7 see 40/44/55/60/62 series relay see 60/62 series relay
Nominal voltage (V)250 see 40/44/55/60/62 series relay see 60/62 series relay
Max voltage (V)400 250 see 40/44/55/60/62 series relay see 60/62 series relay
Rated load AC1 (VA) 2500 1750 see 40/44/55/60/62 series relay see 60/62 series relay
Standard contact materialAgNi see 40/44/55/60/62 series relay see 60/62 series relay
Nominal voltage (VAC 50/60Hz)12÷240 12÷24 12÷240
Nominal voltage (VDC)12÷125 12÷24 12÷240
Rated power AC VA (50 Hz)2 150 mW 1.2 W
Rated power DC W2 150 mW 1.2 W
Functions AI, DI, SW, GI AI AI, DI, SW, BE, CE, DE, EE, FE
Specified time range(0.05÷1)s, (0.5÷10)s, (5÷100)s, (0.5÷10)min, (5÷100)min, (0.5÷10)h, (5÷100)h (1.5÷15)s, (6÷60)s, (0.8÷8)min, (6.4÷64)min (0.05÷1)s, (0.5÷10)s, (5÷100)s, (0.5÷10)min, (5÷100)min, (0.5÷10)h, (5÷100)h
Electrical life at rated load in AC1 (cycles)200·103 150·103 see 40/44/55/60/62 series relay see 60/62 series relay
Protection categoryIP20 IP20
Ambient temperature range (°C)-20÷+60 -20÷+50
Approvals: (according to type)CE GOST cULus CE GOST cULus CE
Unit weight (g)50 5 42
Boxed quantity (units)1 1
Sockets94 Series 92/94/95 Series 90/92 Series

FUNCTIONS
U = Supply Voltage
S = Start
C = Relay contact (NO)
AE
ON delay: timing on START release (external start)
AI
ON delay
AIa
ON delay: (2 timed contacts)
AIb
ON delay: (1 timed contact + 1 instantaneous contact)

BE
OFF delay: timing on START release (external start)
BI
True OFF delay (power off)
CE
ON and OFF delay (external start)
DE
ONĘpulse: timing on START pulse
DI
ON pulse
DIa
ON pulse: (2 timed contacts)
DIb
ON pulse: (1 timed contact + 1 instantaneous contact)

for 86 Serie


for 87 Series

EE
OFF pulse: timing on START releasel
FE
ON pulse - OFF pulse: timing on Start pulse and on START release
GI
Fixed pulse (0.5 s) delayed
HI ON pulse
LE Asymmetrical recycler: pulse start (external start)
LI
Asymmetrical recycler: pulse start
PE
Asymmetrical recycler: pulse start (external start)
PI
Asymmetrical recycler: pause start
SD
Star - delta
SP
Symmetrical recycler: pause start
SW
Symmetrical recycler: pulse start


Finder SpA. - ITALY - Tel. +39 0119 346 211 - Fax +39 0119 359 079